Agent: | Cu | Fe | Mn | Ni | Pb | Sn | Zn | Other | Mass-volume g/cm3 |
Mini: | 47,0 | - | 1,5 | 6,0 | 2,3 | - | Reste | - | 8,5 |
Maxi: | 50,0 | 0,3 | 3,0 | 8,0 | 3,3 | 0,2 | - | 0,2 |
State | Nominal size of the straight section | Tensile strength Rm N/mm² min. |
Conventional elastic limit at 0,2Rp0,2 N/mm² |
Stretching | Hardness | |||||
HB or HV | ||||||||||
Diameter mm | Size on flat mm | |||||||||
from | until and included | from | until and included | A100mm % min. | A11,3 % min. | A % min. | approx | |||
M | 2 | 50 | 2 | 40 | ||||||
R510 | 2 | 50 | 2 | 40 | 510 | -400 | 8 | 10 | 12 | -150 |
R590 | 2 | 20 | 2 | 16 | 590 | -500 | -2 | -3 | 5 | -170 |
R680 | 2 | 5 | 2 | 5 | 680 | -600 | - | - | - | -200 |
State | Nominal size of the straight section | Hardness | Tensile strength | Conventional elastic limit at 0,2 % | Stretching | ||||
Rm | Rp0,2 | A% | |||||||
Diameter mm | Size on flat mm | ||||||||
from | until and included | from | until and included | HB min. | HV min. | N/mm² approx. | N/mm² approx. | approx. | |
M | All sizes | ||||||||
H110 | 6 | 80 | 6 | 60 | 110 | 115 | -460 | -250 | -12Mechanical properties of wires (EN 12166 |
State | Diameter | Tensile strength Rm N/mm² |
Conventional elastic limit at 0,2Rp0,2 N/mm² |
Stretching | Hardness HV | ||||||
from | more than | until | min. | Max. | A100mm % min. | A11,3 % min. | A % min. | min. | max. | ||
M | 1,5 | - | 12,0 | - | - | - | - | - | - | - | - |
R520 | 1,5 | - | 12,0 | 520 | - | -250 | 12 | 15 | 18 | - | - |
H130 | 1,5 | - | 12,0 | - | - | - | - | - | - | 130 | 170 |
R620 | 1,5 | - | 10,0 | 620 | - | -500 | -3 | 5 | 7 | - | - |
H160 | 1,5 | - | 10,0 | - | - | - | - | - | - | 160 | 200 |
R700 | 1,5 | - | 5,0 | 700 | - | -620 | - | - | - | - | - |
H190 | 1,5 | - | 5,0 | - | - | - | - | - | - | 190 | 230 |
State | Sizes | Tensile strengt Rm N/mm min. | Conventional elastic limit a 0,2Rp0,2 N/mm | Stretching A % | Hardness | |||
Section | Rectangular bars thickness mm | |||||||
> at | < or = | HB min. | HV min | |||||
M | All | All | ||||||
R650 | - | - | 6 | 650 | -450 | -5 | - | - |
H170 | - | - | 6 | - | - | - | 170 | 180 |
R600 | - | 6 | 60 | 600 | -400 | -8 | - | - |
H150 | - | 6 | 60 | - | - | - | 150 | 155 |